Project case study

Brewery AD effluent treatment project

 
Balmoral Tanks case study

What was installed:

Buffer tank Ø9.4m x 16.4m high. Epoxy coated tank with a 20° conical roof structure. Net capacity, including freeboard, 1057m3.

Biobed tank Ø7.8m x 18m high. Stainless steel with externally beamed stainless steel roof structure. 70mbar test pressure. Net capacity, including freeboard, 808m3.

Flash aeration tank Ø7.8m x 8.1m high. Epoxy coated with 20° conical roof structure. Net capacity, including freeboard, 337m3.

Conditioning tank Ø1.5m x 18m high. Stainless steel tank with externally beamed stainless steel roof structure. 70mbar test pressure. Net capacity, including freeboard, 30m3.

The conditioning tank is a company ‘first’ it being the smallest diameter/highest tank we have ever designed, fabricated and installed.

Water testing was carried out by the client while gas and air tests to pressures given above were tested by Balmoral.

Application Anaerobic effluent treatment plant
Tank types efusion™ and stainless steel
No of tanks
4
Total capacity
2232m3
Scope of work
Design, supply, install, test
Contact us to find out how we can help you solve your current technical challenge

CASE STUDIES